- Home
- ยป
- Our Product Range
- »
- Waste Water Treatment Plant
Waste Water Treatment Plant
SEWAGE TREATMENT PLANT
The Spectrum Aqua Pvt Ltd produces equipment and facilities for wastewater treatment. The business has over twenty-three years of experience in the water sector and has provided cutting-edge water treatment solutions to municipal, industrial, and mining clients. To tackle any technical or environmental difficulty, The Puredrop offers advanced water assets.
RO Plants, Softeners, ETP, DM Plants, Chillers, AMC, O&M, Ultra Filtration, UV, Ozonation, ZLD Plants, and other goods and services are available from Puredrop.
We provide services to businesses in textile, pulp and paper, beverage, refinery, schools, hospitals, office blocks and hotels.
OFFERINGS AND ASSISTANCE
Wastewater pollutants are to be lessened through Sewage Treatment Plants (STPs). Both home and commercial wastewater can be treated with them. They are a particular category of waste management facility, and their primary goal is to lessen the amount of contaminants in the water. STPs are frequently used to raise water quality in urban areas. A full-scale household STP can handle the wastewater produced by up to 60,000 persons.
Sewage Treatment Plant Stp
| AMC Provided | Yes |
| Application Industry | Food Industry |
| Capacity (KLD/MLD) | 100 KLD |
| Feed Flow Rate(m3/day or m3/hr) | 100 m3/day |
| Water Pump Power | 1 KW |
| Automation Grade | Automatic |
| Impurities To Be Removed | Oil & Grease |
| Deliver Type | PAN India |
| Warranty | 1 Year |
| Treatment Stages | Primary Treatment |
| Air Blower Count | 1 Blower |
| Control Module | Available |
๐ TECHNICAL DATASHEET – 100 KLD STP
1. General Information
|
Parameter |
Description |
|
Plant Capacity |
100 KLD (100,000 litres/day) |
|
Technology Used |
MBBR or SBR (based on project requirement) |
|
Influent Type |
Domestic Sewage / Municipal Wastewater |
|
Effluent Quality |
BOD < 10 mg/L, TSS < 10 mg/L, COD < 50 mg/L |
|
Design Flow |
100 m³/day |
|
Peak Flow Factor |
2.0 |
|
Operating Hours |
24 Hours/Day |
2. Process Description
For MBBR-Based STP:
- Screening Chamber – Removal of floating solids.
- Oil & Grease Trap – Separation of oils and grease.
- Equalization Tank – Flow balancing.
- Aeration Tank (MBBR) – Biological treatment with media.
- Secondary Clarifier – Solid-liquid separation.
- Treated Water Tank – Collection of treated water.
- Sludge Holding Tank – Storage of excess biological sludge.
- Chlorine Contact Tank / UV Disinfection – Pathogen removal.
For SBR-Based STP:
- Equalization
- SBR Reactors (Fill, React, Settle, Decant)
- Sludge Handling
- Disinfection
3. Civil Structure Sizing (MBBR-Based, Approx.)
|
Unit |
Size (L×B×H) in meters |
|
Screening Chamber |
1.2 × 1.2 × 1.5 |
|
Oil & Grease Trap |
1.2 × 1.2 × 1.5 |
|
Equalization Tank |
4.0 × 3.0 × 3.0 |
|
Aeration Tank |
6.0 × 4.0 × 3.5 |
|
Clarifier |
Dia. 3.0 × 3.5 Depth |
|
Treated Water Tank |
4.0 × 3.0 × 3.0 |
|
Sludge Holding Tank |
3.0 × 2.0 × 2.5 |
|
Chlorination/UV Tank |
1.5 × 1.5 × 2.0 |
4. Electrical & Mechanical Components
|
Equipment |
Specs |
|
Air Blowers |
2 nos. (1W+1S), 5 HP each |
|
Submersible Pumps |
3 nos., 2 HP each |
|
Diffusers |
Fine bubble diffusers |
|
Control Panel |
Automatic with PLC/Timer |
|
Disinfection System |
Chlorine Dosing / UV Unit |
5. Treated Water Use
- Toilet Flushing
- Landscaping
- Floor Washing
- Cooling Tower Makeup
6. Flow Direction:
Screening → Oil Trap → EQ Tank → Aeration → Clarifier → Treated Water → Disinfection → Reuse/Discharge
Stp Sewage Treatment Plant
Minimum Order Quantity: 1 Piece
Product Brochure
| Treatment Capacity | 500 KLD |
| Treatment Technology | Mixed Bed Bio Reactor(MBBR) |
| Capacity | 500 KLD |
| Water Source Type | Industrial Wastewater |
| Capacity (KLD/MLD) | 1kLD to 500 kld |
| Feed Flow Rate(m3/day) | 51-100 m3/day |
| Application of Treated Water | Discharge to Drain |
| Installation Type | Complete Civil Work |
| Material of Construction | Mild Steel |
| Country of Origin | Made in India |
Technical Datasheet – 500 KLD Sewage Treatment Plant
1. General Information
|
Parameter |
Details |
|
Capacity |
500 KLD (500,000 Liters per Day) |
|
Application |
Residential, Commercial, Industrial |
|
Treatment Technology |
Extended Aeration / MBBR / SBR / MBR |
|
Discharge Standard |
CPCB / PCB Norms (BOD < 10 mg/L, TSS < 10 mg/L) |
2. Process Description
|
Stage |
Description |
|
Bar Screen Chamber |
Removes large solids and floating matter |
|
Oil & Grease Trap |
Separates oil and grease from wastewater |
|
Equalization Tank |
Maintains uniform flow and load balancing |
|
Anoxic Tank (Optional) |
Denitrification – helps in nitrate removal |
|
Aeration Tank |
Biological treatment using aerobic bacteria |
|
Secondary Clarifier |
Settles biomass and recycles activated sludge |
|
Tertiary Treatment |
Pressure sand filter (PSF), Activated carbon filter (ACF), UV/Chlorination |
|
Sludge Handling |
Sludge drying beds or mechanical dewatering (filter press/centrifuge) |
3. Design Parameters
|
Parameter |
Value |
|
Influent BOD |
200–300 mg/L |
|
Influent COD |
400–600 mg/L |
|
Treated BOD |
< 10 mg/L |
|
Treated COD |
< 50 mg/L |
|
MLSS in Aeration Tank |
3000–4000 mg/L |
|
F/M Ratio |
0.15–0.25 |
|
HRT (Total) |
18–24 Hours |
|
Sludge Generation |
0.25–0.35 kg/kg of BOD removed |
4. Major Components & Equipment
|
Component |
Quantity & Description |
|
Bar Screen |
1 No., MS/SS Fabricated Manual or Mechanical |
|
Oil & Grease Trap |
1 No., RCC/FRP Tank |
|
Equalization Tank |
1 No., RCC Tank, ~150–200 m³ |
|
Aeration Tank |
1 No., RCC Tank, ~300 m³ |
|
Diffused Aeration System |
Air Blowers (2W + 1S), Diffusers, Piping |
|
Secondary Clarifier |
1 No., RCC/FRP Tank with scraper/mechanism |
|
Filter Feed Pumps |
2 Nos. (1W + 1S), 5 HP each |
|
PSF + ACF Unit |
1 Set, FRP/MS Vertical Vessels |
|
Disinfection Unit |
UV System / Chlorine Dosing |
|
Sludge Handling Unit |
Drying Beds / Filter Press / Centrifuge |
|
Control Panel |
PLC/MCC Panel with SCADA (Optional) |
Additional Information:
- Item Code: PD_500-KLD
- Delivery Time: Within 24 Hours